Time-in-range in clinical trials- Revital Nimri

HbA1c is not an exact reflection of mean glucose. The clinical trials showed that the difference in absolute value between Glucose management indicator (GMI) and HbA1c is more than 0.5. GMI and HbA1c are similar but not identical as they measure different things. Continuous glucose monitoring (CGM) measures direct glucose levels while HbA1c measures the glycation of the red blood cells. Various factors like genetic individual glycation rate, race and ethnicity, aging, pregnancy, drugs and therapies, physiological diseases, etc. alter the measured HbA1c. Multiple studies have demonstrated the efficacy and safety of CGM and a growing number of people are using CGM. Time in range (TIR) is becoming popular for assessing glycemic control in practice and research. They enable personalized care and are endorsed by professional societies. A systemic review showed a rapid surge in publications using TIR as a clinical outcome. TIR and other CGM metrics have important implications for clinical care and research and add more dimensions to glycemic control. The growing evidence supports the beneficial effect of greater TIR on reducing the risk of long term diabetes complications. The consensus guidelines provide a standardized approach for using CGM in clinical studies. TIRs and other CGM metrics should be used along with HbA1c and sometimes alone.

Time-in-range from a regular perspective: Use of data derived from continuous glucose monitoring (CGM), including but not limited to TIR, to support clinical investigations of antidiabetic agents- Patrick Archdeacon

The interest is growing regarding the use of CGM in patients with type 2 diabetes not using insulin. HbA1c and GMI are highly correlated while HbA1c and TIR are moderately correlated providing some complementary information. 24 hour ambulatory glucose profiles provide richer data to inform patient management decisions than summary metrics like A1c, GMI and TIR. FDA considers reduction in A1c to be validated surrogate for microvascular disease risk reduction to support traditional drug approval. TIR is a biomarker that has not been established as a surrogate for a clinical outcome and is not acceptable as the primary endpoint for glycemic-control indication, FDA will consider including relevant CGM-based metrics in the clinical studies section of labeling of drugs approved for a glycemic-control indication with efficacy demonstrated by change in A1c or an appropriate hypoglycemia endpoint, provided that the performance characteristics of CGM devices, data collection and analyses are adequate. FDA considers drugs that can meaningfully reduce iatrogenic hypoglycemia and maintain glycemic control beneficial to patients. Different clinical trial endpoints may be appropriate depending on the clinical goal and the regulatory framework for demonstrating substantial evidence of effectiveness. Self-monitoring blood glucose (SMBG) devices performance is generally considered acceptable and FDA encourages sponsors to obtain agreement of devices to be used. The limitations are that they require subjects to actively obtain blood glucose samples and inadequate characterization of nocturnal hypoglycemia. CGM systems may be more likely to capture events because of the continuous nature of data collection. They may limit bias and improve capture of nocturnal events and events in patients with hypoglycemia unawareness. Because use in the regulatory context is evolving and uncertainties exist regarding use in clinical, FDA encourages sponsors to engage with Agency regarding the use of CGM and CGM-based hypoglycemia endpoints.

Time-in-range in clinical decision support- Daniel DeSalvo

TIR focus enhances the existing models of care. Diabetes care that relies on quarterly visits with A1c checks neglects the reality of life with diabetes that is continuous. Using A1c alone may not be very helpful to patients for understanding their diabetes as there is impact of lifestyle on glycemic management. Wearing CGM allows for personal discovery as patients engage in their own care. FDA-cleared, AI based clinical decision support system (CDSS) for optimizing diabetes treatment provided similar levels of glycemic outcomes as expert physicians. A TIR-focused approach to diabetes care enables population health management by improving the patient experience of care, improving the health of populations and reducing per capita cost of care. A paradigm shift to TIR-focused diabetes care enables therapeutic action in individuals with diabetes. TIR goals should be personalized and adapted. The challenges and opportunities to promote equitable access to CGM and TIR-focused diabetes care persists.

Time-in-range from patient perspective- Kelly L Close

The global CGM user base is growing rapidly as there are estimated 6.7 million CGM users globally. A retrospective CGM data from Barbara Davis Center shows that every 5% decrease in TIR is associated with 16% increased relative risk in developing diabetic retinopathy. There are still many patients with type 2 diabetes taking sulfonylureas (SUs), putting them at risk for hypoglycemia. dQ&A data suggests that this number has hovered around 30% of people with T2D for the last four years. CGM use in patients on SUs can help identify and reduce time below range. There are a growing number of patients who are taking a glucagon like peptide 1 agonist (GLP-1 agonist) and Sodium glucose co transporter 2 inhibitors (SGLT-2i) and are also using CGM. It can offer greater insights into glucose management and can help protect against hypoglycemia. CGM metrics in type 2 diabetes present a massive opportunity. The impact of Time in Range has barely scratched the surface and there is a need to grow and leverage the power of TIR to address specific problems in diabetes.