One-Liter Polyethylene Glycol Plus Low-Dose Ascorbic Acid Safe and Non-Inferior for Bowel Cleansing
Introduction
In individuals undergoing colonoscopy for colorectal cancer screening, bowel preparation with 1-L polyethylene glycol plus ascorbic acid (PEG-ASC) formulation improves patient compliance with comparable bowel cleansing effect, safety and tolerability as that of 2-L PEG-ASC. However, hypernatremia, dehydration, electrolyte disturbance and side effects (nausea and vomiting) are prevalent, which may be due to higher ASC levels.
Aim
To demonstrate the noninferiority of 1-L PEG with low-dose ASC (25.0 g or 37.5 g) as compared to standard 1-L PEG-ASC (50 g) and 2-L PEG-ASC in terms of bowel cleansing efficacy
Patient Profile
- 219 healthy adults who underwent colonoscopy and esophagogastroduodenoscopy (EGD) simultaneously
Method
Study Design
- Randomized, controlled, double-blinded, multicenter, noninferiority trial
- Patients were randomized to 1-L PEG with low-dose ASC, standard 1-L or 2-L PEG-ASC
- The 1-L PEG with low-dose ASC group was subdivided into 3 groups according to the dose of ASC on day 1 (day of starting bowel preparation) and day 2 (day of colonoscopy): group A, ASC 12.5 g each on day 1 and day 2; group B, ASC 25 g on day 1 and 12.5 g on day 2; and group C, ASC 12.5 g on day 1 and 25 g on day 2
Endpoints
- Primary Outcome: Efficacy of bowel cleansing - two scales were used simultaneously: Harefield Cleansing Scale (HCS) in the right-sided colon, transverse colon, descending colon, sigmoid colon, & rectum and Boston Bowel Preparation Scale (BBPS) in the right-sided colon, transverse colon, and left-sided colon
- Secondary Outcomes: Polyp detection rate and adenoma detection rate in the right-sided colon and overall colon
- Tolerability: overall satisfaction scores, willingness to repeat colonoscopy with the same agent, ease of consumption, overall experience, and taste of the preparation agent
- Safety: adverse event (AE), clinical and laboratory evaluations, vital signs, and physical examinations
Results
Efficacy
- As per the HCS, 1-liter PEG with low-dose ASC [group A (P = 0.495 and 0.235), group B (P = 0.495 and 0.235), and group C (P = 1.000 and 0.611)] demonstrated a statistically noninferior success rate of bowel cleansing as compared to the standard 1-L and 2-L PEG-ASC groups, respectively; the bowel cleansing rates as per HCS in the right-sided colon is shown in Figure 1
- Similarly, according to BPPS, 1-liter PEG with low-dose ASC [group A (P = 0.495 and 0.235), group B (P = 0.495 and 0.235), and group C (P = 0.495 and 0.235)] demonstrated a statistically noninferior success rate of bowel cleansing as compared to the standard 1-L and 2-L PEG-ASC groups, respectively
- The bowel cleansing rate in the other colonic segments did not differ among the groups
- No significant difference was observed in the adenoma detection rate, right-sided adenoma detection rate or polyp detection rate among the 5 groups
Figure 1: Effect of 5 PEG-ASC groups on bowel cleansing rates in the right-sided colon
Safety
- 1-L PEG with low ASC and standard 1-L PEG-ASC groups achieved significantly better overall satisfaction score versus the 2-L PEG-ASC group (P = 0.009)
- Overall satisfaction score and experience with the preparation agent were significantly better in group A (P = 0.003 and 0.021, respectively), group B (P = 0.025 and 0.073, resp.), and group C (P = 0.002 and 0.041, resp.) versus the 2-L PEG-ASC group
- The ease of consumption of the preparation agent was also better in group A (P = 0.004), group B (P = 0.048), group C (P = 0.002), and the standard 1-L PEG-ASC group (P = 0.058) versus the 2-L PEG-ASC group
- The willingness to repeat colonoscopy with the same agent was higher in group A (P = 0.030), group B (P = 0.080), and group C (P = 0.015) than in the 2-L PEG-ASC group
- The groups did not differ in terms of the ability to consume the preparation agent (P = 0.105) and taste of the preparation agent (P = 0.269)
- Residual fluid retention was significantly lower in groups A to C (53.5-70.6 mL) and the 2-L PEG-ASC group (40.6 mL) versus the standard 1-L PEG-ASC group (99.9 mL, P = 0.029)
- No significant difference in the overall incidence of AEs among the groups (P = 0.530)
- The incidence of mild AEs (nausea, vomiting, abdominal pain, dehydration, and headache) was not significantly different among the groups (P = 0.530), and only nausea occurred in >5% of the participants
- No serious AEs or deaths occurred
- The incidence of gastroduodenal erosion, ulcer on EGD (P = 0.545), rates of a >10% electrolyte shift from baseline (P = 0.125) or clinically significant electrolyte change (P = 0.243) were not significantly different among the groups
Conclusion
One-liter PEG with low-dose ASC (25%-50% reduction in dose) for bowel cleansing was non-inferior compared with standard 1-L or 2-L PEG-ASC with similar safety, better tolerability versus 2-L PEG-ASC, and less residual gastric fluid retention versus standard 1-L PEG-ASC.
Gastrointest Endosc 2022; 96: 341-50